5ch SEPARATELY CONTROLABLE
5kV OUTPUTS |
REF/
HP5x01 |
HP5x5
|
|
| The HP5x5 provides 5 separately controlled 0 to 5kV outputs, at up to 300µA. Each one can be configured by the factory as positive or negative ( combinations of polarity are possible, e.g. 3 positive and 2 negative ). Each channel is controlled by its own 0 to +10V control signal, and each has its own 0 to +10V monitor output. The module is powered from +24V.dc, and draws 2 amps fully loaded. |
|
|
HP5x5 pin connection & safety instructions |
| Input voltages: | +24 volt at 2 amp. Negative input terminal common to HV earth return |
| Output Voltage 1: | 20V to 5kV at 300µA. |
| Output Voltage 2 to 5: | As output 1. All outputs are individually controlled. |
| Polarity: | Each channnel can be factory set either positive or negative (combinations such as 3 positive & 2 negative are possible). |
| Please note the following applies to each of the 5 outputs: | |
| Controls ( 5 separate ): | 0 to +10V gives 0 to 5kV. |
| Voltage monitors: | 0 to +10V represents 0 to 5 kV (all 5 outputs). Source resistance 10 kohm. |
| Ripple: | Less than 150mV peak to peak on each output. |
| Line regulation: | Less than 50ppm for 1V change in input. |
| Load regulation: | Less than 50ppm. |
| Output Tolerance: | Better than 2% of control voltage. |
| Temperature coefficient: | Better than 200ppm per °C. |
| Operating temperature: | 0°C to +45°C. |
| Size: | 216 x 155 x 52mm |
| Output cables: | By flying leads. Each cable 0.5 metre of URM43 |
| Input connector: | Molex 6 way &12 way connector. |
| Ordering Information: |
State unit type HP5x5 and polarity mixture
e.g. HP5x5-3PN2N (3 positive and 2 negative). |
|
|
Applied Kilovolts Ltd.
webSite: http://www.appliedkilovolts.com/ |
|
|
38 - 40 Eastbrook Road, Portslade, Sussex, BN41 1PB, United Kingdom Phone: +44 (0) 1273 439 440 Fax: +44 (0) 1273 439 449 |
||
Local distributor in Japan
|
|
APACE Science, Inc.
webSite:
http://www.apace-science.com/ Mitomo-Bldg.#2 - 6F, Ebisu-nishi 2-Chome, 2 - 8, Shibuya-Ku, Tokyo 150-0021 Phone: +81 (0)3 - 3463 - 3204 Fax: +81 (0)3 - 3463 - 3205 |
| | Applied Kilovolts TopPage | PageTop | specials | detailed photo | APACE Home | |