| SAFETY & INSTALLATION INSTRUCTIONS | ( September 2001 ) |
| FOR HP & KS SERIES |
| PLEASE READ CAREFULLY BEFORE INSTALLING OR OPERATING THIS POWER SUPPLY |
|
|
| Pin 1 | Synchronisation (HP Series only). | Pin 6 | Link to pin 5 for external control. |
| Pin 2 | + 24 Volt power input. | Pin 7 | Analogue voltage input 0 to +10V gives 0 to max. O/P. |
| Pin 3 |
Voltage monitor. 0 to +10V
represents 0 to max. output. Tol .... HP Series + 2%, Input impedance > 100 k.ohms. KS series + 3%. Source resistance 10 kohms. |
Pin 8 |
HP Series I monitor
( if fitted ). KS Series + 500V tap ( if fitted ). |
| Pin 4 | Control link, see diagrams above. | Pin 9 | Signal 0 volt return. |
| Pin 5 | Control link, see diagrams above. | Pin 10 | Power 0 volt return. |
|
Connector details:
Molex® mating halves are 10 pin socket 1001 1104 and the pins are part number 0850 0108 Unit weights (approximate unpacked weight):
|
|
GENERAL
On receipt the unit should be carefully unpacked and inspected to ensure that no transit damage has occurred. Provided that this inspection is satisfactory and reveals no evidence of damage then installation can proceed. If an electrical test is to be carried out prior to fitting the power supply, it is essential that the person undertaking this work be a qualified electronics technician who is fully aware of the particular dangers associated with high voltage switch mode power supplies. Metallic or conductive tools should not be used to adjust any of the potentiometers. The unit has no user serviceable parts and should not be dismantled.
DO NOT HANDLE OR TOUCH THESE UNITS WHEN THE SUPPLY IS CONNECTED.
AFTER DISCONNECTION FROM THE SUPPLY, ALLOW 30 SECONDS BEFORE
HANDLING SO THAT ALL THE CAPACITORS CAN DISCHARGE.
Care should be taken not to operate the unit outside the specified
limits given above, failure to do so may damage the unit.
COMPLIANCE WITH SAFETY STANDARDS
a.
A
b.
The output is classed as hazardous and must therefore not be
accessible to operators.
The output must be isolated from accessible circuits by Double
Insulation or a protective screen as defined in EN61010-1.
c.
The unit is intended to be installed in an electrical enclosure
and should not be accessible to the operator.
Access should be restricted to authorised service personnel
only, with use of a tool.
Care should be taken to prevent access to the interior of
the unit and protect against items (e.g. tools or wires)
inadvertently entering the interior of the unit.
INSTALLATION
Under worst case conditions the unit draws a current of 1A (HP)
and 0.5A (KS) and any input supply cable must be of a suitable
type and rating.
The unit is not fitted with a fuse and so should be operated
from a limited supply.
Fuses may be fitted externally to the unit to protect unit and
interconnecting wiring etc. but these should be rated to prevent
nuisance failures.
Care should be taken in the design of the interconnecting wiring
within the system to ensure that connectors with hazardous
voltages cannot be connected to accessible circuits.
Ensure that the output is connected to the load prior to operation
of the unit and that a good low impedance high voltage joint is made.
Sharp points on either the high voltage or return joint should be
avoided as this will cause corona which will make the output appear
noisy.
In general a tracking distance (creepage distance) of 25mm
(1 inch), per 10kV to earth is advised as a minimum to ensure
no breakdown or corona occurs, a much greater distance will be
required under adverse conditions.
Care must be taken not to damage the cable inner when forming
the connections.
During arcing currents exceeding 1000 Amps will flow.
It is important that these currents return to the high voltage
power supply by the shortest possible route using the screen
(shield) of the output cable.
Failure to observe this will result in the control terminals of
the unit seeing large voltage spikes during arcing and radiation
of electromagnetic interference.
Adequate ventilation should be provided to keep the unit cool and
the ventilation inlets should not be covered in any way.
The ambient air temperature around the inlet must
OPERATING NOTES
2/ The unit is short circuit proof but care should be taken
that the high voltage cannot be shorted into one of the control pin
connections.
3/ KS SERIES ONLY. R101 sets the oscillator frequency, in
the event of this pot being disturbed it can be reset by adjusting
for minimum input current at full load and full output voltage.
4/ POWER SUPPLIES ARE DISPATCHED WITH INTERNAL POTENTIOMETER
SET TO MAXIMUM.
TURN DOWN TO ZERO BEFORE CONNECTING TO 24 VOLT SUPPLY.
|