PIN ASSIGNMENT & INSTALLATION INSTRUCTIONS FOR   LS   SERIES

    for internal Potentiomenter operation (FP)
    links are factory fitted internally
      15W D type plug       15W D type plug
 
ORDERING CODES
series code kv polarity options code temp code
LS 001 = 1kV
2.5 = 2.5kV
005 = 5kV
P = +ve
N = -ve
   IP = Precision I mon
   PP = + Internal Reference
   FP = + Internal Pot & Reference
10
  e.g. LS010NIP010 = 10kV negative LS without Pot & Ref options
  For Internal or External Potentiometer operation the PP or FP option codes must be specified.

pin 1: analogue input voltage 0 to 10V gives 0 to max O/P pin 9: analogue voltage input return
pin 2: internal 10V reference - if fitted pin 10: precision Imon (0-10V = 0 to max I )
pin 3: signal 0V for monitor signals
  (connected internally to pin 4)
pin 11: Vmon Signal (0-10V = 0 to max V)
pin 4: signal 0V for monitor signals
  (connected internally to pin 3)
pin 12: enable High = +24V = Enable O/C
or OV = inhibit (do not use as safety interlock)
pin 5: power 0V (Internally connected to pins 6 & 7) pin 13: 24V supply (connected internally to 14 & 15)
pin 6: power 0V (Internally connected to pins 5 & 7) pin 14: 24V supply (connected internally to 13 & 15)
pin 7: power 0V (Internally connected to pins 5 & 6) pin 15: 24V supply (connected internally to 13 & 14)
pin 8: not connected    
     Note: Control Voltage (pin 1) must be between -0.5V & 10.2V
     Enable i/p has a 100k Internal pull-down to 0V power

mounting
M4 blind fasteners to front and rearof base. max screw depth 4mm.

cleaning
use a lint free cloth soaked with isopropyl alcohol, ensuring the unit is completely dry before use.

environmental conditions
  • indoor use only
  • altitude up to 2,000m
  • operating temperature 0°C to +50°
  • storage temperature -35°C to +85°C
  • maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C
  • the unit is to be supplied from a current limited supply
  • providing 24Vdc, impulse limited to (overvoltage) category I of IEC60364-4-443
  • for use in an environment of pollution degree 2

| Page Top | LS datasheet |   | APACE top-page |