Applied Kilovolts Zero Crossing Reversible
High Voltage modules
REF/
HPR97A
HP2.5RZC, HP3RZC, HP5RZC
& HP8RZC
detailed photo of HPRZC
Applications
  • Bipolar Lens Supplies

  • Mass Spectrometers

  • Focus &High Voltage Bias    
UNIT
TYPE

OUTPUT

RIPPLE AT
FULL LOAD

OUTPUT
DEAD SPACE

(output voltage undefined)
HP2.5RZC -2.5 kV to +2.5 kV at 400µA 250 mV peak to peak -100 mV to +100 mV
HP3RZC -3 kV to +3 kV at 400µA 250 mV peak to peak -100 mV to +100 mV
HP5RZC -5 kV to +5 kV at 400µA 500 mV peak to peak -350 mV to +350 mV
HP8RZC -8 kV to +8 kV at 400µA 1 V peak to peak -500 mV to +500 mV

pin connections & instructions

Electrical Specification
Input voltages: +24 V +10% at 1 A and -15 V +5% at 25 mA.
Output voltage: See table above.
Control voltage: -10 V to +10 V give -max. kV to +max. kV
(e.g. -2.5 kV to +2.5 kV).
NB: internal manual potentiometer control not fitted.
Load regulation: Less than 100 ppm for zero to max. load.
Line regulation: Less than 20 ppm for 1 V change in I/P volts.
I monitor: 0 to +10 V represents 0 to +500 µA, 0 to -10 V represents 0 to -500 µA.
Speed of response: Better than 10 mS measured on a 5 kV peak wave between 10% & 90%.
Temperature co-efficient: 25 ppm per °C.
Operating temperature: 0 C to +45 °C.

Mechanical Specification
Size: 216mm x 155mm x 52mm.
NB. Grounding of the case is via fixing bolts.
Output cable: URM43 length 0.5 meter.
Input Connector: BERG 20 Way IDC header, mating connector and 300 mm of ribbon cable supplied.

Applied Kilovolts Applied Kilovolts Ltd.
  webSite:   http://www.appliedkilovolts.com/
38 - 40 Eastbrook Road, Portslade, Sussex,
BN41 1PB, United Kingdom
Phone: +44 (0) 1273   439 440       Fax: +44 (0) 1273   439 449
   Local distributor in Japan
APACE Science   APACE Science
APACE Science, Inc.     webSite:   http://www.apace-science.com/
Mitomo-Bldg.#2 - 6F, Ebisu-nishi 2-Chome,
2 - 8, Shibuya-Ku, Tokyo 150-0021
Phone: +81 (0)3 - 3463 - 3204       Fax: +81 (0)3 - 3463 - 3205  

| Top of Page | specials | Detailed Photo | APACE Science Home |