Radiation Sensors
NaI(Tl) scintillation detectors |
Distributed by
|
| integral type detectors |
|
detector
model |
crystal dimensions | housing dimensions | PMT size | ||||
| diameter | thickness |
crystal part
diameter |
PMT part
dia. (max) |
length | |||
| 6S4P2 |
38.1mm
( 1.50inch ) |
25.4mm
( 1.00inch ) |
44.5mm
( 1.75inch ) |
58.7mm
( 2.31inch ) |
152.4mm
( 6.00inch ) |
2 inch | |
| 6S6P2 |
38.1mm
( 1.50inch ) |
38.1mm
( 1.50inch ) |
44.5mm
( 1.75inch ) |
58.7mm
( 2.31inch ) |
165.1mm
( 6.50inch ) |
2 inch | |
| 6S8P2 |
38.1mm
( 1.50inch ) |
50.8mm
( 2.00inch ) |
44.5mm
( 1.75inch ) |
58.7mm
( 2.31inch ) |
177.8mm
( 7.00inch ) |
2 inch | |
| 7S4P2 |
44.5mm
( 1.75inch ) |
25.4mm
( 1.00inch ) |
50.8mm
( 2.00inch ) |
58.7mm
( 2.31inch ) |
152.4mm
( 6.00inch ) |
2 inch | |
| 7S8P2 |
44.5mm
( 1.75inch ) |
50.8mm
( 2.00inch ) |
50.8mm
( 2.00inch ) |
58.7mm
( 2.31inch ) |
177.8mm
( 7.00inch ) |
2 inch | |
|
|||||||
|
|
|
detector
model |
crystal dimensions | housing dimensions | PMT size | ||||
| diameter | thickness |
crystal part
diameter |
PMT part
dia. (max) |
length | |||
| 8S4P2 |
50.8mm
( 2.00inch ) |
25.4mm
( 1.00inch ) |
58.7mm
( 2.31inch ) |
58.7mm
( 2.31inch ) |
152.4mm
( 6.00inch ) |
2 inch | |
| 8S8P2 |
50.8mm
( 2.00inch ) |
50.8mm
( 2.00inch ) |
58.7mm
( 2.31inch ) |
58.7mm
( 2.31inch ) |
177.8mm
( 7.00inch ) |
2 inch | |
|
|||||||
|
|
|
detector
model |
crystal dimensions | housing dimensions | PMT size | ||||
| diameter | thickness |
crystal part
diameter |
PMT part
dia. (max) |
length | |||
| 12S4P3 |
76.2mm
( 3.00inch ) |
25.4mm
( 1.00inch ) |
82.6mm
( 3.25inch ) |
58.7mm
( 2.31inch ) |
165.1mm
( 6.50inch ) |
3 inch | |
| 12S8P3 |
76.2mm
( 3.00inch ) |
50.8mm
( 2.00inch ) |
82.6mm
( 3.25inch ) |
58.7mm
( 2.31inch ) |
190.5mm
( 7.50inch ) |
3 inch | |
| 12S12P3 |
76.2mm
( 3.00inch ) |
76.2mm
( 3.00inch ) |
82.6mm
( 3.25inch ) |
58.7mm
( 2.31inch ) |
215.9mm
( 8.50inch ) |
3 inch | |
|
|||||||
|
|
|
General specifications / series S - P Housing: Spun aluminum: 1/32" wall thickness Reflector: Al2O3 packed powder: 1/16" thick, 67mg/cm2 Radiation entrance window Aluminum: 0.010" thick, 68.5mg/cm2 for crystals up to and including 3" diameter. Aluminum: 0.020" thick, 137mg/cm2 for crystals over 3" in diameter. Photomultiplier tube: Unless specified, Radiation Sensors will select a suitable photomultiplier tube. A large selection of manufacturers and photomultiplier tube types are available upon specific request. Resolution: Pulse Height Resolution (PHR) will range from 10% to 6.5% based on FWHM for the @662keV of 137Cs peak line. Integral Detectors with guaranteed premium resolution are available at extra cost.
|
|
|
|
Radiation Sensors, LLC.
NaI(Tl) scintillation detectors |
|
|
|
| page top | Radiation Sensor Home webSite | APACE Science TopPage | |
|